J. For. Sci., 2004, 50(2):86-100 | DOI: 10.17221/4604-JFS

Assessing the effect of a coating system on the rate of plywood moistening and changes in dimensions in relation to the change in relative air humidity

P. Král, J. Hrázský
Faculty of Forestry and Wood Technology, Mendel University of Agriculture and Forestry, Brno, Czech Republic

The paper summarizes results of an institutional research aimed at the evaluation of the effect of a coating system on the rate of plywood moistening and changes in dimensions in relation to changes in relative air humidity. Coefficients of dimensional changes were determined in relation to relative air humidity and effects were studied of the coating system on the rate of plywood moistening. All measurements were carried out in water-resistant combined plywood with surface coating and thickness of 8, 10, 12, 15 and 18 mm and in all-beech plywood 10, 12, 15 and 18 mm in thickness. Based on the results obtained it is possible to state that bending strength and modulus of elasticity are decisively affected by the construction of a sheet. Therefore, it is suitable to select the sheet structure according to requirements of a customer. It is known that surface layers transfer the greatest stress and that the stress of layers decreases towards the axis of symmetry. The fact can be used in designing the sheet structure, e.g. using veneers manufactured from cheaper species for central layers. Thus, the price and even density of plywood can be substantially reduced maintaining the required strength. By means of coats it is possible to reduce substantially penetration of moisture across the plywood edge. Comparisons between polyurethane coat U 2070 and acrylate coat AQUACOL V 2080 are demonstrated in a figure. Changes in the length and width of combined plywood and all-beech plywood amount to on average 0.020-0.025% per 1% change in moisture. Under upper values of the moisture range the changes are generally substantially lower. In practice, a suitable clearance for changes in the length and width of plywood amounts to 2 mm/m. Changes in thickness reach on average 0.4-0.5% per 1% changes in the moisture content.

Keywords: plywood; moisture; hygroscopicity; polyurethane coat; acrylate coat; dimensional changes

Published: February 29, 2004  Show citation

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
Král P, Hrázský J. Assessing the effect of a coating system on the rate of plywood moistening and changes in dimensions in relation to the change in relative air humidity. J. For. Sci. 2004;50(2):86-100. doi: 10.17221/4604-JFS.
Download citation

References

  1. HORÁČEK P., 1998. Fyzikální a mechanické vlastnosti dřeva I. [Skripta.] Brno, MZLU: 128.
  2. POŽGAJ A., 1997. Štruktúra a vlastnosti dreva. Bratislava, Príroda: 486.
  3. ČSN EN 313-1 Překližky. Klasifikace a názvosloví. Český normalizační institut, 1995: 6.
  4. ČSN EN 313-2 Překližované desky. Klasifikace a terminologie. Český normalizační institut, 1995: 8.
  5. ČSN EN 322 Dosky z dreva. Zisťovanie vlhkosti. Český normalizační institut, 1993: 8.
  6. ČSN EN 323 Dosky z dreva. Zisťovanie hustoty. Český normalizační institut, 1994: 8.
  7. ČSN EN 325 Dosky z dreva. Stanovenie rozmerov skúšobných telies. Český normalizační institut, 1995: 8.
  8. ČSN EN 326-1 Desky ze dřeva. Odběr vzorků, nařezávání a kontrola. Část 1: Odběr vzorků, nařezávání zkušebních těles a vyjádření výsledků zkoušky. Český normalizační institut, 1997: 12.
  9. ČSN EN 315 Desky ze dřeva. Rozměrová tolerance. Český normalizační institut, 1995: 8.
  10. ČSN 49 0181 Preglejky. Spôsob zisťovania zmien lineárnych rozmerov v závislosti od relatívnej vlhkosti vzduchu. Československý normalizační úřad, 1986: 6

This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International (CC BY NC 4.0), which permits non-comercial use, distribution, and reproduction in any medium, provided the original publication is properly cited. No use, distribution or reproduction is permitted which does not comply with these terms.